Sloped Bottom Vertical Tanks with IMFO®

Sloped Bottom Vertical Tanks with IMFO®Traditional tank maintenance can be a challenge with many chemicals – so Poly has developed a unique sloped bottom tank system that greatly minimizes the hazards associated with traditional vertical tank maintenance. With Poly Processing’s Sloped Bottom Integrally Molded Flanged Outlet tank, or IMFO® system, the flange is molded while the tank is processing, making it a stress-free part of the tank. The floor of the tank is sloped towards the IMFO giving the user the greatest possible full drain system in a vertical tank design.

The Sloped Bottom IMFO’s advantages are many:

  • The flange is at the bottom of the tank and the tank floor is sloped, therefore complete full drainage is achieved below the tank knuckle radius, which eliminates the need to enter the tank for cleaning.
  • One-piece construction enhances long-term performance of the tank, since it doesn’t compromise the tank hoop’s integrity or structural design.
  • In aggressive applications, the complete flange face is protected by the antioxidant OR-1000™ system.
  • The Sloped Bottom IMFO allows even heavier materials such as sludge, FOG, and thicker chemicals to discharge completely.

For additional information on Sloped Vertical Tanks, download the guide below.

Download Now

For specific questions about vertical tanks with IMFO®, please contact a Poly Processing chemical storage tank expert.

Talk to a chemical storage tank expert

Documents

Specifications

Sloped Bottom Vertical Tanks with IMFO®

Columns in the table below with arrows in the heading can be sorted by clicking the arrows.

Lugs Drawing Gal. Per Inch Chart Stock Number F.O.B. Nominal Capacity Approx. O.D. Approx. Height Lid Size IMFO Size Ladder Height Tank Weight
L 2D CAD 2D PDF 3D CAD PDF 1215000 LA 15000 13'-9" 16'-5" 24" 4" 16' 5000
L 2D CAD 2D PDF 3D CAD PDF 1213200 LA 13200 13'-9" 14'-7" 24" 4" 15' 4400
2D CAD 2D PDF 3D CAD PDF 1211800 CA 11800 12'-0" 16'-4" 24" 4" 15' 4200
L 2D CAD 2D PDF 3D CAD PDF 1209850 CA 9850 12'-0" 14’-1 1/2” 24" 4" 14' 3800
2D CAD 2D PDF 3D CAD PDF 1208500 CA 8500 12'-0" 12'-7" 24" 4" 13' 2650
L 2D CAD 2D PDF 3D CAD PDF 1206350 LA 6350 10'-2" 12'-10 3/4" 24" 4" 13' 1800
L 2D CAD 2D PDF 3D CAD PDF 1206250 CA 6250 10'-0" 13'-0" 24" 4" 13' 1600
L 2D CAD 2D PDF 3D CAD PDF 1204200 CA 4200 8'-2" 13'-5" 24" 3" 12' 1100
L 2D CAD 2D PDF 3D CAD PDF 1204100 VA 4100 8'-6" 12'-7 3/4" 24" 3" 13' 1050
L 2D CAD 2D PDF 3D CAD PDF 1203950 CA 3950 10'-0" 9'-1" 24" 4" 8' 1100

• = Molded-in lifting lugs

L = Molded-in ladder attachment lugs

Weights are approximate for shipping estimates only.

Polyurethane PolyBase

Columns in the table below with arrows in the heading can be sorted by clicking the arrows.

Tank Diameter Stock Number Drawings
8'-6" 68186000671 2D CAD 2D PDF 3D CAD
8'-2" 68182000671 2D CAD 2D PDF 3D CAD
10'-2" 68110200671 2D CAD 2D PDF 3D CAD
10'-0" 68110200671 2D CAD 2D PDF 3D CAD
12'-0" 68112000671 2D CAD 2D PDF 3D CAD

Crosslinked PolyBase

Columns in the table below with arrows in the heading can be sorted by clicking the arrows.

Tank Diameter Stock Number Drawings
8'-6" 8100086 2D CAD 2D PDF 3D CAD
10'-2" 8100102 2D CAD 2D PDF 3D CAD
10'-0" 8100010 2D CAD 2D PDF 3D CAD
12'-0" 8100012 2D CAD 2D PDF 3D CAD

PolyBase IMFO and Sloped Bottom IMFO support systems are available for all Vertical Tanks with IMFO and Sloped Bottom Tanks with IMFO. Please contact Poly Processing Company for your PolyBase needs.